There is insufficient bone tissue below the implantation site. We are preparing a new product fixture. Surrounding autologous bone is collected. Synthetic bone and autogenous bone are used to cover the inferior area. Synthetic bone and autogenous bone are used to cover the inferior area.
A 51-year-old male patient. Implant placement is planned for the maxillary tooth #26 area. Due to inadequate bone on the palatal root side, an extraction was performed with simultaneous socket preservation. Implant placement was performed after approximately 4 months of socket preservation. Here is a photo of the implant in place. Implants from Ossteo Bionics, specifically the SB implants, were placed during the procedure. The implant was placed using a crestal approach in the maxillary area, and BioCrea was used for grafting during implant placement. This is a post-operative radiograph after the surgery. The bone density at the time of implant placement was approximately D3. Here is a brief summary of the implant surgery record I use: I always make sure to record the bone quality, initial stability, and generally, I note down the expected prosthetic placement date at the time of implant placement. Here is a photo taken about 3 months after implant placement. While I don't always m...